RSREX / MTRGEX Explosion‑Proof China Roots Blower | VOC Waste‑Gas Recovery | SHANGU MingTian

SHANGU® RSREX / MTRGEX Explosion-Proof Roots Blowers for VOC Waste-Gas Recovery & Abatement
Product Overview
For chemical plants, printing, coating, petrochemical tank farm and pharmaceutical industry VOC volatile-organic-compound waste-gas projects, explosion-proof roots blowers serve as core process equipment for waste-gas collection, pressurized conveying, oil-vapor recovery, gas recirculation for RTO / CO / zeolite-rotor systems.
SHANGU® RSREX, MTRGEX explosion-proof tri-lobe roots blowers are purpose-built by Shandong Mingtian Machinery Group, Made-in-China with US-Japan reference-grade technology for hazardous VOC service with flammable solvent vapour, trace corrosive components and condensate risk. As positive-displacement equipment, they deliver stable volumetric airflow under fluctuating pipeline resistance and variable VOC concentration.
Suitable for common organic waste-gas, oil-vapor, condensable solvent steam and low-corrosive process exhaust. Widely deployed in chemical parks, printing & packaging, automotive coating, petrochemical tank-farm oil-vapor recovery, pharmaceutical synthesis waste-gas treatment, rubber-plastic industry exhaust abatement. Material options include standard HT250 cast-iron housing & rotors, heavy-duty epoxy coating, optional 304 / 316 L stainless-steel rotors and casings for corrosive VOC-containing exhaust.
Rare Practical Field Tips (Seldom Published Online)
- All catalogue nominal data are under standard suction condition (20 ℃, 101.3 kPa, RH 65 %) clean-air basis. VOC waste-gas has different molecular-weight & density compared with air. Never select model directly by air-based catalogue values; correction for gas molecular-weight, inlet temperature and altitude must be completed. Add an 8-12 % flow margin for every 1000 m elevation rise. Mass-flow capacity drops sharply when inlet temperature exceeds 45 ℃.
- Critical selection pitfall for VOC project: explosion-proof motor alone cannot guarantee full-unit intrinsic safety. Anti-static rotor, flame-arrestor protection, multi-stage sealing, nitrogen-purge interlock and vent pipeline shall be equipped as a full package. Static-discharge ignition risk still exists if only motor is changed.
- Strictly distinguish Normal-state flow Nm³/min (0 ℃ for environmental-assessment report) vs actual working-condition flow Qs m³/min (20 ℃ blower inlet). Most EIA reports adopt normal-state flow, while blower performance is measured under working condition. Wrong conversion leads to insufficient gas-collection and fugitive emission. Conversion formula: Qs=Qn×1.0732
- VOC solvent vapour condenses inside casing during cooling process. Ordinary single-labyrinth seals will be quickly eroded by condensate liquid. Double-end mechanical seal with isolating-purge-gas port is mandatory; simple labyrinth-type seal is not acceptable.
- Excessive margin should be avoided. If flow-pressure margin exceeds 30 %, unit runs far from high-efficiency zone with over 20 % extra power-consumption. Reasonable process margin for VOC projects: 10-15 %.
- Backflow risk for VOC system is higher than ordinary air service. Swing check-valve alone is insufficient. Vacuum-breaking valve, vent pipeline and nitrogen-purge interface shall be equipped for shutdown organic-vapor displacement, preventing combustible-vapor accumulation hazard.
Applicable Industry Standards
- JB/T 8941.1-2014: Roots type blowers for general purpose — Part 1: Specification
- JB/T 8941.2-2014: Roots type blowers for general purpose — Part 2: Performance test method
- JB/T 13233-2017: Explosion-proof roots blowers (Chinese industry standard for combustible-gas service)
- GB 3836 series: Chinese explosive-atmosphere standards, MOD (Modified Adoption) of IEC 60079, comparable with EU ATEX 2014/34/EU directive.
- HJ/T 251-2006: Environmental-protection product technical requirement for roots blowers.
- GB/T 2888-2008: Method of noise measurement for fans and roots blowers.
- GB 28381-2026: Minimum allowable values of energy-efficiency and energy-efficiency grades for blowers.
Standard Equivalence Note
- JB/T 8941.1-2014 is MOD (Modified Adoption) of ISO 1217:2009 Displacement compressors — Acceptance tests, NOT identical adoption. Overseas ISO 1217 lab test-reports serve only for reference. Domestic Chinese VOC-abatement projects shall perform final acceptance complying with JB/T & JB/T 13233-2017 & GB 3836 standards.
- GB 3836 ≈ IEC 60079 ≈ EU ATEX directive: equivalent but not fully identical. Separate ATEX certification is mandatory for EU export; domestic GB 3836 test-reports cannot replace EU-ATEX certificates.
Unit-Conversion Reference (For Tender & Cross-border Comparison)
Pressure:
9.8 kPa = 0.1 kgf/cm² = 1000 mmH₂O = 1.422 psi
Flow:
1 m³/min = 60 m³/h = 35.71 CFM
Gas-state conversion: Working-condition suction-state flow Qₛ (20 ℃) = Qₙ (0 ℃) × 1.0732
Important VOC project remark: Clearly mark working-condition / normal-state flow, Gauge / Absolute pressure in inquiry documents. Provide gas molecular-weight, air-based conversion formula cannot be directly applied for organic-vapor media.
Key Buyer Concerns (Explicit Requirements & Hidden Field Pain-points)
✅ Explicit Requirements
- Working-condition flow & pressure matching total pipeline resistance and RTO / zeolite-rotor system load;
- Explosion-proof rating matching hazardous-zone classification (Ex d ⅡB T4 / Ex d ⅡC T4);
- Noise & vibration comply with chemical-plant site environmental limits;
- Initial-investment budget and motor-power requirement;
- PLC-compatible, VFD-ready for fluctuating waste-gas volume & concentration.
✅ Hidden Pain-points (Safety & production-loss risk outweighs equipment price gap)
- Condensate-solvent seal-erosion risk: Condensed solvent vapour destroys ordinary seals, leading to fugitive organic-gas leakage, triggering both environmental-violation and safety hazards. Double-mechanical-seal with isolating-purge-gas design is required.
- Full-unit intrinsic-safety requirement: Explosion-proof motor is only single component. Anti-static rotor, flame-arrestor, nitrogen-purge port and vent-interlock shall be fully equipped. Single-part explosion-proof ≠ full-unit explosion-proof.
- 24/7 continuous heavy-duty reliability: Chemical & petrochemical production runs non-stop all-year-round. Units ≥ 60 kPa(gauge) shall adopt water-cooling construction. Overheating, oil emulsification and unexpected shutdown will paralyze entire VOC-treatment system and cause direct waste-gas discharge violation.
- Selection error caused by mixing normal-state / working-condition parameters: Many projects adopt Nm³/min data from environmental-assessment report without temperature & molecular-weight correction, resulting in insufficient actual blower output and poor waste-gas capture.
- Total-lifecycle-cost thinking: Evaluate power consumption, special-spare-part cost, outage loss, environmental-penalty and safety-risk instead of focusing merely on procurement price. Low-cost simplified-configuration units bring severe hidden hazards.
- Customization & after-sales support: VOC is high-risk medium. Manufacturer shall provide gas-property calculation, full-set explosion-proof-configuration advice, safety-oriented installation briefing and fast spare-part delivery for emergency breakdown.
Core Product Advantages | SHANGU® by Shandong Mingtian Machinery Group
Shandong Mingtian Machinery Group is national Hi-Tech Enterprise and national-level Specialized-Sophisticated “Little-Giant”. Made-in-China manufacturing adopting US-Japan reference-grade technology standards. Two industrial parks are equipped with 5-axis machining centers, high-speed dynamic-balancing testers and three-coordinate measuring instruments. The R&D team includes professor-level senior engineers, PhD and master specialists with university-industry-research cooperation. SHANGU® is a well-known trademark of Shandong Province.
- Constant-volume anti-back-pressure performance: Tri-lobe rotors pass G2.5-grade high-speed dynamic balancing. Stable working-condition airflow even under variable waste-gas load and pipeline resistance, guarantee high waste-gas-collection efficiency.
- Complete VOC-oriented explosion-proof & corrosion-resistant customized solutions:
- Explosion-proof package: Exd ⅡBT4 / Exd ⅡCT4 explosion-proof motor, anti-static rotor; reserved ports for flame-arrestor, nitrogen-purge displacement and vent interlock pipeline.
- Sealing solution: Double-end fluororubber mechanical-seal with isolating-purge-gas port, resisting erosion from condensed solvent liquid.
- Corrosion-resistant option: Heavy-duty epoxy coating for ordinary VOC service; 304 / 316 L stainless-steel rotor & casing for medium containing H₂S or acidic solvent.
- Enhanced water-cooling for high-pressure duty: Units ≥ 60 kPa(gauge) equipped with circulating water-cooling system for non-stop 7 × 24-h full-load chemical-plant service.
- VOC-optimized full-scope package supply: Precision inlet filter, flame-arrestor assembly, inlet-outlet silencers, safety relief valve, swing check-valve, vent-valve unit, anti-vibration base, anti-static flexible expansion joints. Optional explosion-proof VFD cabinet automatically adjusts airflow following waste-gas-load change, delivering 18-30 % energy-saving.
- Full-scope factory acceptance test: Each unit undergoes performance, explosion-proof index, noise & vibration test complying with JB/T 8941, JB/T 13233-2017, GB 3836 series. Complete test-report documentation available for tender and export-EPC-project acceptance.
- Full-process-technical-service: Multi-dimensional condition-calculation including gas-molecular-weight, inlet-temperature and altitude; safety-oriented installation briefing; retrofitting for legacy VOC blowers; regular explosion-safety maintenance guidance.
Application Scenario & Model-Selection Reference
Selection tips: Reserve 10-15 % margin for flow-pressure parameters. Choose MTRGEX water-cooled explosion-proof series for pressure>88.2 kPa. Confirm explosion-proof, sealing & purge-gas configuration for VOC organic-gas service. 1 operating + 1 standby configuration recommended for critical chemical-plant VOC-abatement systems. Perform condition correction for high-altitude & high-inlet-temperature; strictly distinguish working-condition vs normal-state flow.
| Application Scenario | Working-condition Description | Recommended Model | Working-condition Flow(m³/min) | Gauge Pressure(kPa) | Motor Power(kW) | Remarks |
|---|---|---|---|---|---|---|
| Small-medium printing / coating-workshop VOC waste-gas collection | Printing-packaging & small-coating line, intermittent duty, fluctuating VOC concentration, short-to-medium pipeline | RSREX100 | 5-18 | 49-68.6 | 7.5-30 | Full-unit explosion-proof, double-mechanical-seal; VFD optional; flame-arrestor connection port reserved |
| Pharmaceutical / rubber-plant medium-size chemical VOC treatment | Pharmaceutical-synthesis & rubber-processing, trace solvent-condensate, continuous-run | RSREX150A | 18-35 | 58.8-88.2 | 30-75 | Water-cooling recommended for pressure>60 kPa; nitrogen-purge port as standard; upgrade stainless-steel for corrosive-components |
| Large-scale chemical-park, complete-set RTO / zeolite-rotor system | Large-chemical-production-line, long-pipeline, 7×24-h non-stop service, complex multi-component waste-gas | MTRGEX250 | 35-60 | 68.6-117.6 | 75-132 | Mandatory water-cooling; full anti-static explosion-proof + double-mechanical-seal; 1-op-1-standby recommended |
| Petrochemical tank-farm oil-vapor recovery & large chemical tail-gas boosting | Tank-farm oil-vapor recovery, long-distance high-load pipeline, oil-condensate-containing medium | MTRGEX300 | 60-105 | 88.2-120 | 90-160 | Heavy-duty water-cooled unit; customize material & sealing after medium-assay; site-survey & pipe-resistance calculation required |
| Auxiliary VOC service: waste-gas recirculation & adsorber desorption purging | Large-flow low-pressure duty for RTO gas recirculation, activated-carbon-tank desorption air supply | RSREX175A~RSREX200 | 15-48 | 29.4-58.8 | 22-90 | Explosion-proof configuration, optimized for large-flow low-pressure circulating-gas supply |
Model Explanation
- RSREX Series: General-purpose explosion-proof tri-lobe roots blower (belt / coupling drive), for medium-low-pressure VOC waste-gas collection, intermittent & continuous-run duty.
- MTRGEX Series: Mingtian heavy-duty water-cooled explosion-proof roots blower, engineered for high-pressure, long-distance, 24-h hazardous chemical-plant VOC service, with built-in cooling-water ports plus integrated sealing-purge connection ports.
Installation & Maintenance Guidelines (critical for hazardous VOC service, rarely published online)
- Never subject pipeline weight onto blower flanges. Install anti-static flexible expansion joints both on inlet & outlet to isolate pipe-stress and vibration transmission.
- For combustible VOC waste-gas: install flame-arrestor on suction side; equip nitrogen-purge port for organic-vapor displacement before maintenance; route vent-pipe to safe zone. Hot-work on blower casing is strictly forbidden.
- Install filter-elements in cooling-water circuit for regular descaling for water-cooled models.
- Perform shift-based inspection of working pressure, running current, bearing temperature and seal solvent-leakage; regularly carry out combustible-gas-leakage test; shorten inspection interval for seal & purge-gas supply system.
- Inspect rotor abrasion-corrosion and seal-ageing during annual shutdown maintenance; replace wearing-parts proactively to avoid medium-leakage-caused safety & environmental incidents.
Disclaimer: All tabulated parameters serve for general-reference only. For real-world projects, please provide waste-gas-component, gas molecular-weight, working-condition / normal-state flow, required gauge pressure, hazardous-zone classification, total-pipe-length & elbow-quantity, inlet-gas temperature and site altitude. Our technical engineers will deliver condition-corrected custom proposal.
Inquiry — Please provide below information for customized solution & formal quotation
Kindly send your project-parameters, our engineering-team will prepare tailor-made blower-solution and formal commercial quotation:
- Waste-gas medium composition & gas molecular-weight;
- Flow value: distinguish working-condition flow or normal-state flow (m³/min or CFM); required working gauge / absolute pressure(kPa / psi);
- Application type: VOC waste-gas collection, oil-vapor recovery, RTO recirculation, adsorber desorption or others;
- Hazardous-zone classification for explosion-proof-rating definition;
- Pipeline-data: total pipe-length, elbow-quantity;
- Operation-mode: intermittent / 24-h continuous-running;
- Special-requirements: VFD, explosion-proof grade, stainless-steel upgrade, nitrogen-purge interface, standby-unit requirement;
- Power-supply-standard (voltage & frequency);
- Site-ambient-condition: altitude, average inlet-gas temperature;
- Any other site-specific safety & process-requirements.
Contact Us
- 📞 Phone / WhatsApp: +86 187 6611 7068
- 📧 Email: [email protected] | [email protected]
- 🌐 Official Website: https://www.mtrootsblower.com
- 📞 WhatsApp / Wechat: +86 187 5316 3090
- 📧 Email: [email protected]